CGZNZ - S-202 STATIC DISSIPATIVE TILE ADHESIVE

Product Identification

Product ID:S-202 STATIC DISSIPATIVE TILE ADHESIVE
MSDS Date:10/01/1991
FSC:8040
NIIN:00N021315
MSDS Number: CGZNZ

Responsible Party
ARMSTRONG WORLD INDUSTRIES INC
313 W LIBERTY ST
LANCASTER, PA 17604
US

Emergency Phone: 717-396-2328; 717-396-2935

Info Phone: 717-396-2328; 717-396-2935

Cage: 03938

Contractor
ARMSTRONG WORLD INDUSTRIES, INC.
3209 LANCASTER, PA 17604 US

Telephone: 717-396-2328; 717-396-2935

Cage: 03938

Ingredients

ALIPHATIC PETROLEUM DISTILLATE

CAS: 64742-96-7

Fraction By Weight: 4%

OSHA PEL N/K

ACGIH TLV: N/K


NAPHTHALENESULFONIC ACID, FORMALDEHYDE POLYMER AMMONIUM

CAS: 9069-80-1

Fraction By Weight: 3%

OSHA PEL N/K

ACGIH TLV: N/K


AMMONIUM HYDROXIDE; (AQUA AMMONIA (28%)) (CERCLA)

CAS: 1336-21-6

RTECS: BQ9625000

Fraction By Weight: 1%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 4%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SKIN AND EYES: EXCESSIVE SKIN CONTACT
MAY CAUSE DRYING AND CRACKING OF THE SKIN, DEFATTING OF TISSUE AND
RESULT IN DERMATITIS. CONTACT WITH EYES MAY CAUSE IRRITATION. NOT
AN EYE IRRITANT AND NOT A PRI MARY SKIN IRRITANT PER TESTS DEFINED
BY16 CFR 1500. INHALATION: IRRITATION OF RESPIRATORY TRACT, (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:CARBON BLACK: IARC MONOGRAPHS, VOL 65,
PG 149, 1996:GROUP 2B.
Effects of Overexposure:HLTH HAZ: COUGHING, HEADACHE, DIZZINESS,
DROWSINESS, NAUSEA, UNCOORDINATED MOVEMENTS. TARGET ORGANS: SKIN,
EYES, UPPER RESPIRATORY TRACT.
Medical Cond Aggravated by Exposure:ANY CONDITIONS GENERALLY AGGRAVATED
BY EXPOSURE TO AMMONIA OR SOLVENT-BASED RAW MATERIALS. EXISTING
SKIN CONDITIONS.

First Aid

First Aid:EYES: FLUSH EYES WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. REFER TO MD IF IRRITATION OR SYMPTOMS PERSIST. SKIN: FLUSH
SKIN WITH PLENTY OF WATER. WASH WITH SOAP AND WATER. REFER TO MD IF
IRRITATION OR SYMPTOMS PERSIST. INHAL: REMOVE TO FRESH AIR. IF
EXPOSED TO EXCESS CONCENTRATIONS OF VAPOR. SEEK MEDICAL ATTENTION
IF SYMPTOMS PERSIST. INGEST: CALL POISON CONTROL CENTER OR MD FOR
GUIDANCE.

Fire Fighting

Flash Point:>104F,>40C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, HALON, WATER SPRAY.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS IN FIRE MAY RUPTURE DUE
TO PRESSURE BUILD-UP; USE WATER TO COOL CONTAINERS TO PREVENT THIS.

Accidental Release

Spill Release Procedures:VENTILATE AREA OF SPILL OR LEAK. FOR EXPOSURES
ABOVE TLV WEAR NIOSH APPROVED RESPIRATORY EQUIPMENT. CONTAIN SPILL
PREVENTING IT FROM ENTERING SEWER LINES OR WATERWAYS. USE ABSORBENT
TO ASSIST WITH THE PICK-UP OF MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN AREA SUITABLE FOR COMBUST
MIXS. RECOM STOR TEMP IS ABOVE 35F & BELOW 100F. VAPS ARE HVR/AIR.
USE PRECS COMMON W/SAFE HNDLG OF COMBUST PRODS.
Other Precautions:INITIALLY, MAY BE POTNTL ADVERSE IMPACT ON INDOOR AIR
QUALITY W/IN GEN WORK AREA DURING INSTALLATION PROCESS. THEREFORE
ADVISE BLDG MANAGER/OTHER APPROP PERSON THAT IT WILL BE NEC TO
ESTABLISH & MAINT AIN ADEQ VENT OF WORK AREA W/OUT(SUPDAT)

Exposure Controls

Respiratory Protection:WITH ADEQUATE VENTILATION, RESPIRATORY EQUIPMENT
SHOULD NOT BE NEEDED. IF ADEQUATE VENTILATION IS NOT AFFORDED, WEAR
NIOSH APPROVED RESPIRATORY EQUIPMENT APPROVED FOR ORGANIC VAPORS.
Ventilation:USE NATRL CROSS-VENT, LOC (MECH) PICK-UP &/OR GEN AREA
(MECH) VENT TO PVNT ACCUM OF SOLV VAPS, KEEPING IN MIND (SUPDAT)
Protective Gloves:COTTON OR LOOP-PILE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VENT: VENT PATTERN MUST REMOVE HVR/AIR SOLV VAPS FROM LOWER LEVELS OF
WORK SPACES. VENT SHOULD BE SUFFICIENT TO KEEP SOLV VAP CONC BELOW
TLV. OTHER PRECS: CAUSING ENTRY OF CONTAMINANTS TO OTHER PARTS OF
BLDG & PERS WHO ARE SENSITIVE TO ODORS &/OR CHEMS SHOULD BE ADVISED
TO AVOID WORK AREA DURING THIS PROCESS.

Chemical Properties

Spec Gravity:1.0 (H*2O=1)
Solubility in Water:APPRECIABLE
Appearance and Odor:BLACK, HEAVY-BODIED ADHESIVE.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE &
OTHER TOXIC VAPS & GASES THAT ARE COMMON TO THERMAL DEGRADATION OF
ORGANIC COMPOUNDS.

Disposal

Waste Disposal Methods:DO NOT REUSE CONTAINER. DISPOSE OF CONTAINER AND
ANY UNUSED CONTENTS IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
WASTE DISPOSAL REGULATIONS. DO NOT FLUSH UNUSED CONTENTS OR RESIDUE
DOWN DRAINS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their